Extech 433201-NIST Calibrator Thermometer
(115V) with NIST Certificate, One model for multiple thermocouple types with
precision output displayed as mV or °C/°F, Basic accuracy of 0.15% of reading
over wide ranges, Five stored calibration values for fast calibrations, High
accuracy calibration function simulates precision thermocouple outputs for use
in calibrating thermometers, transmitters, controllers or recorders, 0.1°/1°
resolution for J, K, T and E Types; 1° for C, R, S and N Types, °C/°F switchable
for increased versatility, Displays output in terms of millivolts or temperature
based on thermocouple tables, 4 digit LCD display is easy to read with
thermocouple type indication
General Information |
Manufacturer |
Extech |
Manufacturer Part Number |
433201-NIST |
Product Name |
Calibrator Thermometer (115V) with NIST
Certificate |
Features |
- One model for multiple
thermocouple types with precision output displayed as mV or °C/°F
- Basic accuracy of 0.15% of reading
over wide ranges
- Five stored calibration values for
fast calibrations
- High accuracy calibration function
simulates precision thermocouple outputs for use in calibrating
thermometers, transmitters, controllers or recorders.
- 0.1°/1° resolution for J, K, T and
E Types; 1° for C, R, S and N Types
- °C/°F switchable for increased
versatility
- Displays output in terms of
millivolts or temperature based on thermocouple tables
- 4 digit LCD display is easy to
read with thermocouple type indication
- Unique handheld Oyster case design
features large digital display built into “flip-up" cover
automatically shuts off when closed
- Portable and rugged industrial
design for field, plant or benchtop use
- Operates on alkaline batteries,
rechargeable batteries or AC adaptor
- Standard Thermometer Calibration
cables (terminated with subminiature connectors on either side)
comes standard with the meter. Optional Process Calibration Cable is
terminated with spade lug for process applications
- Complete with Type K Thermocouple
calibration cable, Copper calibration cable, 9V NiCad rechargeable
battery, neckstrap for "hands-free" operation, AC adaptor/recharger,
and hard carrying case
|
Specifications |
Type J |
Ranges for Calibrate and Measure modes |
Accuracy |
-58 to 1830°F (-50 to 1000°C) |
0.15% rdg ±1° |
Type K |
-58 to 2498°F (-50 to 1370°C) |
0.15% rdg ±1° |
Type T |
-184 to 752°F (-270 to 400°C) |
0.15% rdg ±1° |
Type E |
-58 to 1382°F (-50 to 750°C) |
0.15% rdg ±1° |
Type C |
32 to 4172°F (0 to 2300°C) |
0.15% rdg ±1° |
Type R |
32 to 3182°F (0 to 1750°C) |
0.15% rdg ±1° |
Type S |
32 to 3182°F (0 to 1750°C) |
0.15% rdg ±1° |
Type N |
-58 to 2372°F (-50 to 1300°C) |
0.15% rdg ±1° |
Voltage |
-5.00mV to +55.00mV 10ìV |
10ìV ±1d |
Resolution |
0.1° (up to 999.9) or 1° (over 999.9°) |
Cold Junction Compensation |
0.03°C/°C (0.02°F/°F) |
Input Impedance |
10 Mohm |
Sampling Time |
4 times/second |
Dimensions |
3.8x4.2x1.8" (96x108x45mm) |
Weight |
17oz |