Protek 6030C, Dual Trace Oscilloscope with Component Tester, 30 MHz Vertical
Bandwidth, LCR Component Tester, x5 Mag for Vertical Input and x10 for
Horizontal, 50/60Hz Frequency, 40W Power Consumption, 50Hz to 10MHz 2 Div
Trigger Lock, TV Synch Filter; Trigger Signal Output; High Brightness CRT with
Internal Graticule.
General Information |
Manufacturer |
Protek
|
Manufacturer Part Number |
6030C |
Product Line |
Oscilloscopes |
Product Name |
6030C, Dual Trace Oscilloscope with Component Tester |
Features |
- 30 MHz Vertical Bandwidth (-3dB)
- LCR Component Tester
- Alternate Trigger for a stable display
of unrelated signals
- x5 Mag for Vertical Input and x10 for
Horizontal
- TV Synch Filter
- Trigger Signal Output
- High Brightness CRT with Internal
Graticule
|
Specifications |
Vertical Amplifier
(CH 1 and CH 2) |
- Sensitivity : 5mV/Div to
20V/Div in 12 steps (1-2-5 seq) / 1mV/Div to 4V/Div (X5 Mag)
- Mag: x5
- Accuracy : ±3% (5% in X5 Mag)
- Bandwidth (-3dB) DC: 0Hz to
30MHz / AC: 10Hz to 30MHz
- Rise Time: < 18ns (<70ns in
X5 Mag)
- Input Impedance : Res - 1MW
±5%; Cap: 30pF
- Input Coupling : AC, DC, GND
- Invert Channel : CH2
- CH1/CH2 Trigger Output :
100mV/Div into 50W
- Display Modes : CH1, CH2,
ALT, Chop, ADD, X-Y
- Maximum Input Voltage : 400V
(DC or AC peak)
|
Horizontal Sweep |
- Sweep Time : 100ns/Div to 0.2s/Div in 20
steps (1-2-5 seq) / 10ns/Div to 20ms/Div (X10 Mag)
- Mag : x10
- Accuracy : ±3% (8% X10 Mag)
- Sweep Modes : TV, Normal and Single
|
Triggering |
- Source : CH 1, CH 2, ALT, Line and EXT
- Slope : Positive or Negative adjustable
levels
- Coupling : AC, DC, Normal/TV
- Sensitivity (Int): DC to 20MHz 1 Div
- Sensitivity (Ext): 0.3V p-p)
- Sensitivity (TV Int): 2 Div
- Sensitivity (TV Ext): 0.3V p-p
- Trigger Lock : 50Hz to 10MHz 2 Div
- External Trigger Input Impedance: 1MW ±5%
/ Maximum Input
- Voltage: 400V (DC or AC p-p)
|
Z Axis Modulation |
- Minimum Input Level : TTL
- Maximum Input Voltage : 50V
or AC p-p
- Polarity : Intensity
increases as the voltage decreases
- Input Resistance : 10KW
- Bandwidth (-3dB) : DC to
5MHz
|
X-Y Mode |
- Inputs : X-Axis (CH1), Y-Axis
(CH2)
- Sensitivity : Same as CH1
- Frequency Response (-3dB)
DC: 0Hz to 1MHz / AC: 10Hz to 1MHz
- Maximum Voltage : Same as
CH1
- X-Y Phase Difference : < 3°
|
Calibrator Signal |
- Waveform : Square Wave
- Amplitude : 0.5V ±2% p-p
- Frequency : 1KHz ±2%
|
Component Test |
A 60Hz, 9V RMS signal is applied to the CH1 and CH2 input when the AC, DC, GND
is in the GND position and the component test button is pushed in
|
General Specifications |
- Power Requirements : AC
Input Voltage: 120V or 220V
- Frequency : 50/60Hz
- Power Consumption : 40W
- Operating Temperature : 0 to
40°C (32 to 104°F)
- Size : 5.1" (H) x 12.5" (W)
x 15.75" (D)
|
A-20060802-1261-109-E
M-20061212-1261-138-E
*This item is BRAND NEW - not refurbished. It comes with all manufacturer supplied accessories, and full manufacturer's USA warranty.
|