AFL OFL280-102-PRO Series OFL280 FlexTester
PRO 1310,1490,1550nm Hand Held Multifunction OTDR and Loss Test Set;
Patented in or out of service OTDR testing from a single port;
Icon-based LinkMap display with pass and fail for easy network
analysis; ServiceSafe live PON detection and OTDR test without
service disruption; UPC AFLOFL280102PRO; Wave ID reduces insertion loss
test time and eliminates setup errors; 34 to 32 dB dynamic range at 1310
to 1550 nm; Best in class 0.8 to 3.5 m event and attenuation dead zones;
Rugged, hand held, lightweight; High contrast, backlit display, easily
viewed, even in direct sunlight; Industry leading battery life, with
more than 12 hours continuous operation; Instant On, Ready to test in
less than 5 seconds; Dimensions (in boot) 7.9" x 5.1" x 2.1"; Weight 1.8
lbs
General Information
|
Manufacturer
|
AFL
|
Manufacturer Part Number
|
OFL280-102-PRO
|
Product Name
|
Series OFL280
FlexTester PRO 1310,1490,1550nm Hand Held Multifunction OTDR and
Loss Test Set |
UPC Code |
AFLOFL280102PRO
|
Overview
|
TFlexTester PRO and PRO2
Kits combine a user selected OFL280 with either the FOCIS PRO or
FOCIS Flex Fiber Optic Connector Inspection System, UPC or APC
connector inspection adapter tips, cleaning supplies, and a rugged, waterproof hard
carry case with room for additional fiber rings and cleaning
supplies
FOCIS PRO and FOCIS Flex enable inspection of ferrule ends of
patch cord connectors and end faces of connectors mounted inside
bulkhead adapters. PRO and PRO2 Kits include LinkMap plus TRM 2.0
Advanced
PRO Kits include FOCIS PRO comprising the DFS1 Digital FiberScope
and hand held DFD1 Touchscreen Tablet. FOCIS PRO includes image
capture, save, AFLs unique imagepairing capability, plus IEC and
user adjustable pass and fail analysis. With FOCIS PRO’s dedicated
Touchscreen Tablet, the OFL280 is available for OTDR and optical
loss testing
|
Features
|
- Patented in or out of service
OTDR testing from a single port
- Icon-based LinkMap display with
pass and fail for easy network analysis
- ServiceSafe live PON detection
and OTDR test without service disruption
- Wave ID reduces insertion loss
test time and eliminates setup errors
- 34 to 32 dB dynamic range at
1310 to 1550 nm
- Best in class 0.8 to 3.5 m event
and attenuation dead zones
- Rugged, hand held, lightweight
- High contrast, backlit display,
easily viewed, even in direct sunlight
- Industry leading battery life,
with more than 12 hours continuous operation
- Instant On, Ready to test in
less than 5 seconds
|
Pictures
|
|
Specifications
|
OTDR
|
|
Emitter
Type Laser
|
Laser
|
Safety
Class Class
|
I FDA
21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
|
Fiber
Type
|
Single-mode
|
Available
Wavelengths
|
1310,
1490, 1550, 1625 nm
|
Wavelength
Tolerance |
+/-20,
+/-20, +/-20, +/-10 nm
|
Dynamic
Range (SNR=1)
|
34,
32, 32, 30 dB
|
Event
Dead Zone |
0.8 m
|
Attenuation
Dead Zone
|
3.5 m
|
Pulse
Widths |
5,
10, 30, 100, 300 ns, 1, 3, 10 µs
|
Range
Settings
|
250 m
to 240 km
|
Data
Points
|
Up to 30,000
|
Data Point Spacing
|
5.0 cm (range less than 1.5 km), Range, 30,000 (range
greater than 1.5 km)
|
Group Index of Refraction |
(GIR) 1.4000 to 1.7000
|
Distance Uncertainty (m)
|
+/-(1 + 0.005 percent x distance + data point spacing)
|
Linearity
|
+/-0.05 dB, dB |
Trace File Format |
.SOR per Telcordia SR-4731 Issue 2
|
Trace File Storage Medium
|
4GB internal memory (greater than 1000 traces)
|
Data Transfer to PC
|
USB cable
|
PON OTDR Modes
|
Test to splitter or through splitter
|
Standard OTDR Modes
|
Full Auto, Expert, Real Time
|
LASER SOURCE
|
|
Emitter Type
|
Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1:
2007-03 |
Fiber Type |
Single-mode
|
Available Wavelengths |
1310, 1490, 1550 nm
|
Wavelength Tolerance |
+/-20 nm
|
Spectral Width (FWHM)
|
5 nm (maximum)
|
Internal Modulation
|
270 Hz, 330 Hz, 1 kHz, 2 kHz, CW
|
Wavelength ID (one, two, or three wavelengths) |
Compatible with AFL Optical Power Meters and Light
Sources |
Output Power Stability
|
0.25 dB
|
Output Power
|
-1 dBm (1310, 1550 nm) +/-1.5 dB; +3 dBm (1490 nm )
+/-1.5 dB |
PON POWER METER FOR SINGLE-MODE ONLY
|
|
Calibrated Wavelengths |
1490, 1550 nm
|
Detector Type |
Filtered InGaAs
|
Isolation |
greater than 40 dB
|
Measurement Range |
+23 to – 50 dBm
|
Accuracy |
+/-0.5 dB
|
Resolution
|
0.01 dB
|
Measurement Units |
dBm or Watts (nW, µW, mW)
|
OPTICAL POWER METER
|
|
Calibrated Wavelengths |
1310, 1490, 1550, 1625, 1650 nm
|
Detector Type |
InGaAs
|
Measurement Range |
+23 to -50 dBm
|
Tone Detect Range |
+3 to -35 dBm
|
Wavelength ID Range |
+3 to -35 dBm
|
Accuracy
|
+/-0.25 dB |
Resolution
|
0.01 dB |
Measurement Units |
dB, dBm or Watts (nW, µW, mW)
|
VISUAL FAULT LOCATOR
|
|
Emitter Type |
Visible red laser
|
Safety Class
|
Class II FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1:
2007-03
|
Wavelength
|
650 +/-20 nm |
Output Power (nominal)
|
0.8 mW into single-mode fiber
|
Modes |
CW, 2 Hz flashing
|
GENERAL
|
|
Operational Temperature |
-10C to +50C
0 to 95 percent RH (non-condensing)
|
Storage Temperature |
-20 °C to +60 °C
0 to 95 percent RH (non-condensing)
|
Power |
Rechargeable Li-Ion or AC adapter
|
Battery Life
|
12 hours, backlight ON, continuous operation
|
Display
|
LCD, 320 x 240, 3.5 inch (89 mm), color, high-contrast
transflective with backlight
and AR coating
|
Dimensions (in boot)
|
7.9" x 5.1" x 2.1 |
Weight |
1.8 lbs
|