Honeywell STT350 Smart Temperature Transmitter,
Direct digital integration with TDC 3000X system provides local measurement
accuracy to the system level without adding typical A/D and D/A converter
inaccuracies, Integral analogue or digital indicating meter option, Write
protect link included to safeguard configuration settings, Single model accepts
input signals from a choice of primary sensors to satisfy varying applications
requirements with minimum transmitter inventory, Standard digital cold-junction
compensation function provides accurate and reliable temperature measurement
over a wide ambient operating range, Added Smart features include reading of the
highest and lowest inputs, external cold junction compensation temperature at an
isothermal block and engineering units displayed in degrees C, F, K, or R plus
milliVolt and Ohms.
General Information |
Manufacturer |
Honeywell |
Manufacturer Part Number |
STT350 |
Product Name |
Smart Temperature Transmitter |
Marketing Information |
STT350 is Honeywell’s high-performance
smart temperature transmitter. The output is transmitted in either an
analog 4-20mA format or Honeywell’s DE protocol format for digital
integration with the Honeywell TPS control system. Select the analog or
digital output format through the Smart Field Communicator (SFC), the
common handheld operator interface for our Smartline™ transmitters, or
with the PC-based SCT 3000 (Smart Configuration Toolkit). All
configuration, operation and communication functions are implemented
remotely from the TPS consoles or through the SFC or SCT.
STT350 transmitters are suitable for new installations as well as
replacements for any conventional or smart temperature transmitters in
use today. The transmitter’s memory contains the characteristics of the
RTD and thermocouple temperature sensors most commonly used. You can
easily use the handheld or PC tool to configure the transmitter for any
of these sensors.
Accuracies stated in the performance specifications below are available
by selecting the sensor type and range (i.e. without user calibration).
Calibration of the LRV/URV end points will typically improve accuracy up
to two times. Sensor errors can be minimized by calibration to the
specific sensor either by setting it at the LRV/URV temperatures or by
simulation of the known values.
Additionally, all units pass through environmental stress screening by
fast cycling between -40 degrees Celsius and 85 degrees Celsius to
ensure maximum product reliability. During this process the ambient
temperature coefficients are determined for each unit and burned into
memory to ensure temperature compensation over a wide range of operating
conditions.
Configuration adjustments and diagnostics checks can be made either
locally or remotely from anywhere along the signal wires. This saves
time during commissioning, startup and maintenance activities. |
Features |
- Direct digital integration with
TDC 3000X system provides local measurement accuracy to the system
level without adding typical A/D and D/A converter inaccuracies.
- Integral analogue or digital
indicating meter option
- Single model accepts input signals
from a choice of primary sensors to satisfy varying applications
requirements with minimum transmitter inventory.
- Standard digital cold-junction
compensation function provides accurate and reliable temperature
measurement over a wide ambient operating range.
- Added Smart features include
reading of the highest and lowest inputs, external cold junction
compensation temperature at an isothermal block and engineering
units displayed in degrees C, F, K, or R plus milliVolt and Ohms.
- Smart transmitter personality with
local or remote interfacing means significant manpower efficiency
improvements in commissioning, start-up, and ongoing maintenance
functions. Write protect link included to safeguard configuration
settings.
- Includes sensor break detection on
all input wires.
- Post read validation of the
measured signal before providing fresh output.
- Suitable for DIN rail mounting or
remote field mounting in a flameproof housing.
- Provides true differential
temperature measurement of thermocouple or RTD inputs by individual
linearisation of each sensor reading and then computing the
difference.
- Suitable for true 4-wire Pt100
measurement (or 3- or 2-wire).
- Write protect link included to
safeguard configuration settings.
- Supports dual thermocouple sensor
inputs for redundant sensor operation.
- Surge/ lightning protection
options can be installed internally in housing or externally in
conduit.
- Supply 11-42 Vdc / Output 4-20 mA
- Temp. Limits -40 to +85ºC
|