General Information
|
Manufacturer
|
Listen
Technologies
|
Manufacturer Part Number
|
D10-1-DANTE
|
Product Name
|
D Series
Dante Single Loop Driver, 10 Amps |
UPC Code |
|
Overview
|
The D10-1-Dante D Series
Single Loop Driver is a 10 Amp single output class D driver;
meaning a 60 percent + increase in energy efficiency over existing
solutions. The driver features capacitive touch front panels with
intuitive menus, built-in test signals, and are fully networkable
with a Wi-Fi accessible standard browser-based control panel for
remote set up, monitoring and email alerts
The D10-1 features a 10 Amp loop output plus ample voltage
headroom, making it the most flexible solution on the market,
suitable for a huge range of applications. The added power of the
D10-1 provides a solution for installations in environments
containing very high levels of metal, previously not possible
without the use of combiners
In another first for high power Class D Induction Loop drivers,
installation can be performed with total confidence, as unique
multi stage filtering ensures compatibility with both other system
equipment and global EMC regulations
|
Features
|
- Dante Input for additional
network audio
- Drives 1 output channels at 10A
RMS
- Networkable with remote browser
interface
- Digital display and intuitive
touch menu system
- 3 modes, Main, Status and Quick
- Highly energy efficient Class-D
amplifier with low heat dissipation
- Up to 1450 sq m Perimeter Loops
area coverage
- Compact 1U rack mount unit with
internal transformer for simple rack installation
- Optimised for speech frequencies
with unmatched intelligibility and capable of high quality
musical reproduction
- AGC and Dual Slope MLC
- Active status monitoring and
remote fault reporting via email
- Data compliant with IEC 62489-1
Standard
|
Specifications
|
Includes |
- One (1) D10-1-Dante D Series
Single Loop Driver (10 Amps x 1) – Dante
- One (1) 1U 19 inches Rack Mount
(brackets included)
- One (1) Handbook and
installation instructions
- One (1) T-Coil Loop System
present Sign (deaf logo)
- Two (2) Neutrik NL4 output
connectors for each output
- One (1) Region specific IEC
power cable
- One (1) Status and DC Connectors
|
Audio
|
|
Frequency
Response
|
80 Hz to 6.3 kHz +/- 3 dB
|
Distortion |
THD+N
Less than 0.2 percent, 1 kHz sine wave at full current
|
AGC
|
Optimized
for Speech, Dynamic Range Greater than 36 dB
|
Metal
Loss Correction
|
Corrects
system frequency response due to metal structures in a building.
Gain constant at 1kHz, adjustable gain slope from 0 to 4dB per
octave in 0.25dB increments. Custom 2 slope MLC allows different
slopes and transition frequency to be set via the menu. This does
not compensate for signal loss from metal structures which can be
significant
|
Phase Shift
|
User selectable at 0 or 90
degrees between outputs
|
Indicators
|
|
AGC LEDs
|
Indicates the status of the
AGC in dB
|
Current LEDs
|
Indicates the peak current
delivered to the loop
|
Clip LED
|
Indicates that the signal
on the loop output is clipping and requires adjustment to either
the driver settings, loop or potentially the selection of a more
powerful driver
|
Error LED
|
Check the Status menu for
loop, amplifier and temperature errors and access fault codes
|
Interconnections |
|
Dante |
RJ45 Ethernet input |
Input 1 |
XLR balanced inputs, switchable between microphone and
line via panel menu: Microphone specification; 200 - 600 Ohm,
sensitivity -64 dBu. Selectable 12 V phantom power on microphone
only. Line sensitivity; -39 dBu, Input Impedance = 17kOhm |
Input 2 |
XLR balanced inputs, switchable between microphone, line
and AES via panel menu: Microphone specification; 200 - 600 Ohm,
sensitivity -64 dBu. Selectable 12 V phantom power on microphone
only. Line sensitivity; -39 dBu, Input Impedance = 17kOhm |
Loop Connector/s |
Channels A / B, Neutrik NL4 Speakon, Drive Current: 14 A
(RMS), 19.8 A (Peak) up to 60 seconds continuous 1 kHz sine wave,
peak Greater than 19.8 A per channel, Cont. pink noise 6.6 (RMS),
short term peaks Greater than 20 A per channel, Drive
Voltage: 33.9 V (RMS), 45 V (Peak) at maximum output current per
channel |
Slave I/O |
6.35mm jack socket for linking more than one amplifier.
Inserting plug disables other inputs |
DC Output |
Resettable, fuse protected 12V 0.1A. Operation can be
configured via menu |
Loop Monitor Connection |
Provides access to monitor actual loop current via a
3.5mm stereo headphone connector on front panel Channel A on left,
channel B on right |
Loop |
|
Perimeter Loop - Coverage |
No Metal (0dB): 1:1 Aspect Ratio 2 x 1000 sq m (10763 sq
ft), 3:1 Aspect Ratio 2 x 1145 sq m (15607 sq ft) |
Loss Control Phased Array - Coverage |
No Metal (0dB): 3300 sq m (35520 sq ft) Moderate Metal
Loss (-5dB): 925 sq m (9956 sq ft) High Metal Loss (-10dB): 400 sq
m (4305 sq ft) Severe Metal Loss (-15dB): N/A |
Low Spill Phased Array - Coverage |
No Metal (0dB): 1225 sq m (13185 sq ft) Moderate Metal
Loss (-5dB): 700 sq m (7535 sq ft) High Metal Loss (-10dB): 340 sq
m (3659 sq ft) Severe Metal Loss (-15dB): N/A |
Power |
|
Power |
120 VAC, 80 W, 45 - 65 Hz, Power Switch on front panel |
Environmental |
|
Temperature - Operation |
0 C (32 F) to 35 C (95 F) |
Cooling |
Variable speed fan cooled. Front inlet, rear exhaust |
Relative Humidity |
20 to 90 percent Relative Humidity |
Standards |
IP20 Rated |
Compliance |
|
Marks and Approvals |
CE and ETL Listed
|
Physical |
|
Mounting |
Freestanding or 1U 19 inches rack mount (brackets
included)
|
Dimensions (H x W x D) |
1.74 x 16.93 x 11.42 inches |
Shipping Weight |
15.2 lb |