General
Information |
Manufacturer |
Maruson
|
Manufacturer Part Number |
ULT-LV10K33
|
Product Name |
Ultima
LV33 Series UPS System 10 to 100KVA 3 Phase 208V/220VAC
|
Overview |
The Ultima LV33 Series Online UPS offers
DSP doubleconversion technology with state of the art PWM
transformerless technology with forth generation IGBT transistor.
Advanced AFC technology provides very low harmonic distortion and
flexibility in single-phase or three-phase setup to withstand all
kinds of diverse loads. It's a best solution for Data Centers,
Telecom & Networking, Industrial, and Medical Applications
Applications: The Ultimate 3 Phase UPS for Data Centers, Telecom
& Networking, Industrial, and Medical Applications |
Features
|
Online double conversion
technology with DSP control
AFC technology for every
low harmonic distortion
Output power factor 0.9
Input current distortion
THDi less than 1 percent
Output efficiency up to 95
percent
Space saving compact
design
Front access makes
maintenance and replacement easy
Control desined to with
stand all kinds of loads
Variety of communication
options available
Touch screen LCD display
panel
Over 60 percent of
materials recyclable
|
Pictures |
|
Specification |
Phase
|
3-Phase in / 3-phase out |
Capacity
|
10KVA / 9KW |
INPUT
|
|
Nominal Voltage
|
3 x 208V (3Ph + N) |
Acceptable Voltage Range
|
+15 or –20 percent
|
Frequency
|
50 / 60Hz more or less 5 percent
|
Total Harmonic Distortion (THDi)
|
Less than 1.5 percent at 100 percent Load, less
than 2.5 percent at 50 percent Load, less than 6.0 percent at 10
percent Load
|
Power Factor
|
0.99 from 10 percent load
|
INVERTER
|
|
Nominal Voltage
|
3 x 208V (3Ph + N) |
Total Harmonic Distortion (THDv)
|
less than 0.5 percent (linear load); less than 1.5
percent (non-linear load)
|
Phase Displacement
|
120 degrees more or less 1 percent (balanced load);
120 degrees more or less 2 percent (imbalances 50 percent of the
load) |
Admissible Overload
|
125 percent to 135 percent for 5 min., 135 percent
to 150 percent for 60 s |
Admissible Crest Factor
|
3.4 : 1
|
Admissible Power Factor
|
0.7 inductive to 0.7 capacitive
|
Current Limit
|
High overload, short-circuit: RMS voltage limit;
high crest-factor current: peak voltage limit
|
STATIC BYPASS
|
|
Type
|
Solid state |
Voltage
|
3 x 208V (3Ph + N) |
Transfer Time
|
Zero |
Admissible Overload
|
400 percent for 10 sec |
Transfer To Bypass
|
Immediate, for overloads above 150 percent
|
Retransfer
|
Automatic after alarm clear
|
MAINTENANCE BYPASS
|
|
Voltage
|
3 x 208V (3Ph + N)
|
Overall Efficiency (Line Mode)
|
90 percent
|
BATTERY
|
|
Built-in Battery Type (2x19)
|
12V 7Ah
|
Max. Charging Current
|
23.5A
|
PHYSICAL
|
|
Dimensions
|
30.3" x 17.7" x 43.3" |
Weight (w / o Battery)
|
207.3 lbs |
Weight (w / built-in Battery)
|
430.0 lbs |