Sencore LC103 ReZolver In-Circuit Capacitor Inductor Analyzer, 3.18 uH to 3.18 H
Inductor Range, Makes all tests, compares the results to EIA standards, 5 volts
peak Exciting Pulse, 0.01 uF to 20 F Capacitor Range, Analyzes capacitors for
all four failures out-of-circuit- Value from 1 pF to 20 F, Equivalent series
resistance, Leakage with up to 1,000 volts applied, Dielectric absorption; Tests
SMT components "in-circuit" and accurately with exclusive, time-saving test
accessories; Makes all tests, compares the results to EIA standards, and tells
you "GOOD" or "BAD" - automatically.
General Information |
Manufacturer |
Sencore |
Manufacturer Part Number |
LC103 |
Product
Line |
General
Analyzing Instruments |
Product
Name |
ReZolver In-Circuit Capacitor Inductor Analyzer |
Marketing Information |
The LC103
ReZolver™ Capacitor and Inductor Analyzer takes the guesswork out of
capacitor and inductor testing. The ReZolver™ is a complete, automatic,
microprocessor-controlled analyzer ideally suited for service,
maintenance, or large volume testing in a lab or incoming inspection.
The ReZolver™ gives you the ability to accurately pinpoint defective
capacitors without removing them from the circuit. Using exclusive tests,
the ReZolver™ measures the capacitor's value and ESR, checks for
parallel components that may otherwise disrupt the measurements, and
gives a GOOD/BAD/SUGGEST REMOVAL evaluation.
Dynamically analyze capacitors out-of-circuit for all four failure modes:
value (to 20 Farads), dielectric absorption (D/A), leakage (up to 1000
applied volts) and equivalent series resistance (ESR). |
Features |
-
Pinpoints bad capacitors and inductors "in-circuit," and
automatically tells you when further out-of-circuit tests are
required
-
Tests
SMT components "in-circuit" and accurately with exclusive,
time-saving test accessories
-
Makes
all tests, compares the results to EIA standards, and tells you
"GOOD" or "BAD" - automatically
-
Analyzes capacitors for all four failures out-of-circuit: Value from
1 pF to 20 F, Equivalent series resistance, Leakage with up to 1,000
volts applied, Dielectric absorption
-
Analyzes inductors with exclusive patented tests for: Values from
0.1 uH to 20 H, Opens or shorts, Even one shorted turn with patented
"Ringer" test
-
Tests
SCRs and triacs with optional SCR250 accessory
|
Specifications |
IN-CIRCUIT TESTS (Capacitors and Inductors): |
Component
Types |
Electrolytic, double layer lytic, tantalum, ceramic, and other
capacitors.
Yokes, flybacks, switching transformers, and coils. |
Inductor Range |
3.18 uH to 3.18 H |
Capacitor Range |
0.002 uF to 20,000 uF |
Accuracy |
Same as Out-of-Circuit tests for known good inductors and capacitors
with no parallel current paths. |
Suggest Removal Indication |
Initiated when AC test differs from DC test by more than 20%,
or if low level DCR test indicates a leakage path greater than 20% of
charge current for capacitors. |
CAPACITORS (Out-of-Circuit) |
Value |
Dynamic test of capacity value is determined by applying a constant
current to the capacitor
and measuring the dV/dt. |
Range |
1 pF to 20 F |
Accuracy |
±1%, ±1 pF, ±1 digit for values to 1990 uF, ±5%;
±0.1% of range full scale for values 2000 uF to 20 F |
EQUIVALENT SERIES RESISTANCE (ESR): |
Accuracy |
±5%, ±1 digit |
Capacitor Range |
0.01 uF to 20 F |
DIELECTRIC ABSORPTION |
Accuracy |
±5% of reading, ±1 count |
Range |
1 to 100% |
Capacitor Range |
0.01 uF to 20 F |
LEAKAGE |
Accuracy |
±5%, ±1 digit |
Applied Voltage |
Keyboard entry 1.0 to 1000 volts in 0.1 volt steps short circuit current
limited to 900 mA |
INDUCTORS
(Out-of-Circuit) |
Value |
A dynamic test of value determined by measuring the EMF produced when a
changing current is applied to the coil under test |
Range |
0.1 uH to 20 H |
Accuracy |
±2%, ±1 digit, ±0.1 uH |
RINGING
TEST |
Inductor Range |
10 uH and larger, non-iron core |
Accuracy |
±1 count on readings between 8 and 13 Rings |
Resolution |
±1 count |
Exciting Pulse |
5 volts peak |
GENERAL |
Temperature Operating Range |
32º to 104º F (0º to 40º C)
Temperature Range for Specified Accuracy (after 10 minute warm-up): 50º
to 86º F (10º to 30º C) |
Power |
105-130V AC, 60Hz, 30 watts with supplied PA251 power adapter.
Battery operation with optional BY289 rechargeable battery. |
Auto-Off |
Removes power during battery operation if unit sits idle longer than 5
minutes. |
Battery Life |
2 hours typical operation |
HxWxD Size |
6" x 9" x 11.5" (15.2 cm x 22.9 cm x 29.l cm) |
Weight |
6.0 lbs. (2.7 kg) without battery, 7.6 lbs. (3.4 kg) with battery |
GOOD/BAD Indication |
Functions on all tests.
Requires user input of component type and value, or input of desired
limits. |