Electronics > Electronic Instruments > General Analyzing Instruments > Sencore LC103 ReZolver In-Circuit Capacitor Inductor Analyzer, 3.18 uH to 3.18 H Inductor Range, Makes all tests, compares the results to EIA standards, 5 volts peak Exciting Pulse, 0.01 uF to 20 F Capacitor Range, Analyzes capacitors for all four failures out-of-circuit- Value from 1 pF to 20 F, Equivalent series resistance, Leakage with up to 1,000 volts applied, Dielectric absorption (LC 103 LC-103)
Sencore LC103 ReZolver In-Circuit Capacitor Inductor Analyzer, 3.18 uH to 3.18 H Inductor Range, Makes all tests, compares the results to EIA standards, 5 volts peak Exciting Pulse, 0.01 uF to 20 F Capacitor Range, Analyzes capacitors for all four failures out-of-circuit- Value from 1 pF to 20 F, Equivalent series resistance, Leakage with up to 1,000 volts applied, Dielectric absorption (LC 103 LC-103)
Sencore LC103 ReZolver In-Circuit Capacitor Inductor Analyzer, 3.18 uH to 3.18 H Inductor Range, Makes all tests, compares the results to EIA standards, 5 volts peak Exciting Pulse, 0.01 uF to 20 F Capacitor Range, Analyzes capacitors for all four failures out-of-circuit- Value from 1 pF to 20 F, Equivalent series resistance, Leakage with up to 1,000 volts applied, Dielectric absorption (LC 103 LC-103)

SKU: LC103

Brand: Sencore

Price: $3,812.09      Add to Cart Qty:    
Estimate Shipping Cost: Chose the quantity to add to cart, press the "Add to Cart" button and in the Shopping Cart press "Calculate Shipping".
 
Bookmark and Share

 

Sencore LC103 ReZolver In-Circuit Capacitor Inductor Analyzer, 3.18 uH to 3.18 H Inductor Range, Makes all tests, compares the results to EIA standards, 5 volts peak Exciting Pulse, 0.01 uF to 20 F Capacitor Range, Analyzes capacitors for all four failures out-of-circuit- Value from 1 pF to 20 F, Equivalent series resistance, Leakage with up to 1,000 volts applied, Dielectric absorption; Tests SMT components "in-circuit" and accurately with exclusive, time-saving test accessories; Makes all tests, compares the results to EIA standards, and tells you "GOOD" or "BAD" - automatically.


General Information

Manufacturer

Sencore

Manufacturer Part Number

LC103

Product Line

General Analyzing Instruments

Product Name

ReZolver In-Circuit Capacitor Inductor Analyzer

Marketing Information

The LC103 ReZolver™ Capacitor and Inductor Analyzer takes the guesswork out of capacitor and inductor testing. The ReZolver™ is a complete, automatic, microprocessor-controlled analyzer ideally suited for service, maintenance, or large volume testing in a lab or incoming inspection.

The ReZolver™ gives you the ability to accurately pinpoint defective capacitors without removing them from the circuit. Using exclusive tests, the ReZolver™ measures the capacitor's value and ESR, checks for parallel components that may otherwise disrupt the measurements, and gives a GOOD/BAD/SUGGEST REMOVAL evaluation.

Dynamically analyze capacitors out-of-circuit for all four failure modes: value (to 20 Farads), dielectric absorption (D/A), leakage (up to 1000 applied volts) and equivalent series resistance (ESR).

Features

  • Pinpoints bad capacitors and inductors "in-circuit," and automatically tells you when further out-of-circuit tests are required
  • Tests SMT components "in-circuit" and accurately with exclusive, time-saving test accessories
  • Makes all tests, compares the results to EIA standards, and tells you "GOOD" or "BAD" - automatically
  • Analyzes capacitors for all four failures out-of-circuit: Value from 1 pF to 20 F, Equivalent series resistance, Leakage with up to 1,000 volts applied, Dielectric absorption
  • Analyzes inductors with exclusive patented tests for: Values from 0.1 uH to 20 H, Opens or shorts, Even one shorted turn with patented "Ringer" test
  • Tests SCRs and triacs with optional SCR250 accessory

Specifications

IN-CIRCUIT TESTS (Capacitors and Inductors):

Component Types

Electrolytic, double layer lytic, tantalum, ceramic, and other capacitors.
Yokes, flybacks, switching transformers, and coils.

Inductor Range

3.18 uH to 3.18 H

Capacitor Range

0.002 uF to 20,000 uF

Accuracy

Same as Out-of-Circuit tests for known good inductors and capacitors with no parallel current paths.

Suggest Removal Indication

Initiated when AC test differs from DC test by more than 20%,
or if low level DCR test indicates a leakage path greater than 20% of charge current for capacitors.

CAPACITORS (Out-of-Circuit)

Value

Dynamic test of capacity value is determined by applying a constant current to the capacitor
and measuring the dV/dt.

Range

1 pF to 20 F

Accuracy

±1%, ±1 pF, ±1 digit for values to 1990 uF, ±5%;
±0.1% of range full scale for values 2000 uF to 20 F

EQUIVALENT SERIES RESISTANCE (ESR):

Accuracy

±5%, ±1 digit

Capacitor Range

0.01 uF to 20 F

DIELECTRIC ABSORPTION

Accuracy

±5% of reading, ±1 count

Range

1 to 100%

Capacitor Range

0.01 uF to 20 F

LEAKAGE

Accuracy

±5%, ±1 digit

Applied Voltage

Keyboard entry 1.0 to 1000 volts in 0.1 volt steps short circuit current limited to 900 mA

INDUCTORS (Out-of-Circuit)

Value

A dynamic test of value determined by measuring the EMF produced when a changing current is applied to the coil under test

Range

0.1 uH to 20 H

Accuracy

±2%, ±1 digit, ±0.1 uH

RINGING TEST

Inductor Range

10 uH and larger, non-iron core

Accuracy

±1 count on readings between 8 and 13 Rings

Resolution

±1 count

Exciting Pulse

5 volts peak

GENERAL

Temperature Operating Range

32º to 104º F (0º to 40º C)
Temperature Range for Specified Accuracy (after 10 minute warm-up): 50º to 86º F (10º to 30º C)

Power

105-130V AC, 60Hz, 30 watts with supplied PA251 power adapter.
 Battery operation with optional BY289 rechargeable battery.

Auto-Off 

Removes power during battery operation if unit sits idle longer than 5 minutes.

Battery Life

2 hours typical operation

HxWxD Size

6" x 9" x 11.5" (15.2 cm x 22.9 cm x 29.l cm)

Weight

6.0 lbs. (2.7 kg) without battery, 7.6 lbs. (3.4 kg) with battery

GOOD/BAD Indication

Functions on all tests.
Requires user input of component type and value, or input of desired limits.

 

A-20080714-1124-130-E

 

*This item is BRAND NEW - not refurbished. It comes with all manufacturer supplied accessories, and full manufacturer's USA warranty.

*** DISCLAIMERS: Some information on this page may have been supplied by 3rd Party Content Suppliers, so we are not responsible for Data or Image errors. Availability is not guaranteed: Call or email us to check stock before placing your order. We do not offer Installation, Training or Technical Support on this product.***

Featured Items:

Ujena 2905T Sheer Brazilian Triangle Bikini Top, Bottom sold Separately as 2905B, Sliding adjustable triangles, Ties at neck and back, No Lining, White Nylon/Lycra fabric (2905-T 2905-TOP 2905TOP 2905)

$44.74

Canon 4214B001 PowerShot SD1300 IS Compact Digital Still Camera with Built-in flash, 4x Optical/4x Digital/16x Combined Zoom with Optical Image Stabilizer System, Silver, 12.1 Megapixel, 1/2.3-inch type Charge Coupled Device (CCD), 2.7-inch TFT color LCD widescreen with wide viewing angle, Shutter Speed 1-1/1500 sec. (4214-B001 4214 B001 SD1300IS SD1300-IS SD-1300IS SD 1300)

$201.23

Home  -  About  Us  -  Contact Us  -  FAQs  -  Financing  - International Shipping - Store Policies - Privacy & Security Policies

Copyright© Sale Stores, All Rights Reserved