System Overview |
System overview:
|
Reliable 24VDC to 120VAC power inverter system serves as an automotive inverter, a battery charger and an uninterruptible power supply. Extended runtime capable with any number of user supplied batteries. 2400 watts continuous / 4800 watts peak. Requires hardwire input & output connection.
|
Voltage compatibility:
|
24VDC / 120VAC
|
Frequency compatibility:
|
60 Hz
|
Output |
Output watt capacity (watts):
|
Continuous - 2400 watts, Overpower (up to 1 hour) - 3600 watts, Double-Boost wattage (up to 10 seconds) - 4800 watts
|
Output nominal voltage:
|
AC OUTPUT: 120VAC nominal, DC CHARGER OUTPUT (DC): 24VDC nominal
|
Output voltage regulation:
|
LINE POWER (AC): Maintains 120V nominal sine wave output. INVERTER POWER (AC): Maintains PWM sine wave output voltage of 120 VAC (+/-5%). DC CHARGER OUTPUT (See battery recharge rate section)
|
Output frequency regulation:
|
60 Hz (+/- 0.3 Hz)
|
Outlet quantity / type:
|
Hardwire AC output
|
Overload protection:
|
Includes 15A input breaker dedicated to the charging system and 15A output breaker for AC output loads
|
Input |
Maximum input amps / watts:
|
DC INPUT: Full continuous load - 112A at 24VDC. AC INPUT: 44 amps at 120VAC with full inverter and charger load
|
Input connection type:
|
DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: Hardwire via built in junction box with cover plate
|
Input cord length:
|
DC INPUT: User supplies cabling. 8 gauge or larger recommended. AC INPUT: user supplies hardwire input cabling
|
Recommended electrical service:
|
DC INPUT: Requires 24VDC input source capable of delivering 112A for the required duration (when used at full continuous capacity). For automotive applications, professional hardwire installation with 300A minimum battery system fusing is recommended.
|
Battery |
DC system voltage:
|
DC input operating range 20-30VDC.
|
Battery recharge rate:
|
Includes selectable 55 / 14 amp DC charging system with selectable profiles for vented wet cell and sealed gel cell batteries. Optional use battery equalize charge function equalizes the charge level when used with multiple batteries (see manual for detailed charger information).
|
Expandable battery runtime:
|
Runtime is expandable with any number of user supplied wet or gel type batteries
|
Leds Alarms & Switches |
Front panel LEDs:
|
Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences.
|
Switches:
|
3 position on/off/remote switch enables simple on/off power control plus "auto/remote" setting that enables distant on/off control of the inverter system when used in conjunction with optional APSRM4 accessory when used in inverter mode. In AC uninterruptible power mode, "auto/remote" setting enables automatic transfer from line power to battery power - to maintain continuous AC power to connected loads.
|
Surge / Noise Suppression |
AC surge suppression:
|
AC surge suppression not included
|
Physical |
Shipping weight (lbs):
|
43
|
Shipping weight (kg):
|
19.5
|
Unit weight (lbs):
|
39
|
Unit weight (kg):
|
17.7
|
Unit Dimensions (HWD/in):
|
7.25 x 8.5 x 16.25
|
Unit Dimensions (HWD/cm):
|
18.4 x 21.6 x 41.3
|
Shipping Dimensions (HWD/in):
|
13.5 x 15 x 21.5
|
Shipping Dimensions (HWD/cm):
|
34.3 x 38.1 x 54.6
|
Material of construction:
|
Polycarbonate
|
Form factors supported:
|
Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting information)
|
Cooling method:
|
Fan
|
Environmental |
Operating Temperature:
|
32-104 Fahrenheit / 0-40 Celcius
|
Relative Humidity:
|
0-95% non-condensing
|
Line / Battery Transfer |
Transfer time from line power to battery mode:
|
4-6 milliseconds
|
Low voltage transfer to battery power:
|
User configurable to 75V, 85V, 95V & 105V
|
High voltage transfer to battery power:
|
User configurable to 135V, 145V
|
Special Features |
Appearance: |
Black color
|
Load Sensing:
|
Optional load sense function enables automatic inverter shutoff and startup as connected equipment is powered off and on. Front panel load sense potentiometer can be set to shutoff or turn on inverter power in response to loads of any level, up to 150 watts.
|