SYSTEM OVERVIEW |
System overview:
|
Standby tower UPS protects PCs, network workstations and other sensitive electronic equipment from blackouts, surges and line noise. Maintains AC output during blackouts and brownouts starting at 99V. Includes basic DB9 serial port, complete cabling and front panel LED indicators. PowerAlert monitoring software available via free download. |
Voltage compatibility:
|
120V AC |
Frequency compatibility:
|
60Hz |
OUTPUT |
Output volt amp capacity (VA):
|
1400 |
Output watt capacity (watts):
|
940 |
Output nominal voltage:
|
120V AC |
Output voltage regulation:
|
LINE MODE: Passes line voltage from 100-176V to connected equipment unchanged. BATTERY MODE: PWM sine wave output 120V +/-5% |
Output frequency regulation:
|
LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz |
Outlet quantity / type:
|
6 NEMA 5-15R |
INPUT |
Maximum input amps / watts:
|
8.25A / 990 watts |
Input connection type:
|
NEMA 5-15P |
Input cord length:
|
6 ft., 14 gauge |
Recommended electrical service:
|
15A 120V |
BATTERY |
Full load runtime:
|
8 minutes (1400VA) |
Half load runtime:
|
24 minutes (700VA) |
DC system voltage:
|
36 VDC |
Typical battery lifespan:
|
3-6 years, depending on usage |
Battery recharge rate:
|
2-4 hours to 90% |
LEDS ALARMS & SWITCHES |
Front panel LEDs:
|
4 front panel LEDs indicate line power status, battery power status, battery low/replace status and overload status |
Alarms:
|
Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain. |
Switches:
|
Includes 2 front panel switches—one main on/off power switch and one dual function "alarm cancel" / "self test" button |
SURGE / NOISE SUPPRESSION |
AC surge suppression:
|
Conforms to IEEE 587 / ANSI C62.41 specifications |
AC suppression response time:
|
Instantaneous |
EMI / RFI AC noise suppression:
|
Yes |
PHYSICAL |
Shipping weight (lbs):
|
38 |
Shipping weight (kg):
|
17.3 |
Unit Dimensions (HWD/in):
|
12.75 x 7.5 x 9 |
Unit Dimensions (HWD/cm):
|
32.4 x 19.1 x 22.9 |
Material of construction:
|
PVC |
Form factors supported:
|
Tower, wall mountable with optional UPSWM accessory |
Cooling method:
|
Convection |
Battery Access:
|
Battery access door allows user replacement of UPS batteries |
ENVIRONMENTAL |
Operating Temperature:
|
+32 to +104 degrees Fahrenheit 0 to +40 degrees Celsius |
Storage Temperature:
|
+5 to +122 degrees Fahrenheit -15 to +50 degrees Celsius |
Relative Humidity:
|
0 to 95%, non-condensing |
COMMUNICATIONS |
Network monitoring port: |
Built-in DB9 port supports on battery, low battery and power restored messaging. Compatible with Tripp Lite's PowerAlert UPS monitoring software. |
Software and cabling included: |
DB9 cabling included |
LINE / BATTERY TRANSFER |
Transfer time from line power to battery mode:
|
2-4 milliseconds |
Low voltage transfer to battery power:
|
Switches to battery power as line voltage decreases to 99 volts or less. Resets back to line power mode as line voltage increases to 104V or higher. |
High voltage transfer to battery power:
|
Switches to battery power as line voltage increases to 176 volts or higher. Resets back to line power mode as line voltage decreases to 172V or less. |
CERTIFICATIONS |
Certifications:
|
UL1778 (USA), cUL (Canada), FCC Class B (emissions), NOM (Mexico) |
WARRANTY |
Product warranty: |
2 year product warranty |
SPECIAL FEATURES |
Cold Start:
|
Yes, inverter can be "cold started" to enable temporary AC output during a power failure |
Appearance:
|
Attractive gray tower UPS |