Machines & Tools > Gasoline/Electric Generators and Generator Accessories > Winco Generators 97714-366 ASCO 185 Series Non-SE Rated Automatic Transfer Switch, 100 Amps, NEMA 3R Housing, #14 to 4/0 AWG Wire Sizing, Single Phase, 2 Poles, 220-240V Low Voltage, User-Friendly Control Interface To Inform Operator Of Transfer Switch And Power Source Status, Transfer To Emergency Time Delay 10 Seconds, Re-Transfer To Normal Time Delay 5 Minutes (WINCO97714366 97714366 97714 366)
Winco Generators 97714-366 ASCO 185 Series Non-SE Rated Automatic Transfer Switch, 100 Amps, NEMA 3R Housing, #14 to 4/0 AWG Wire Sizing, Single Phase, 2 Poles, 220-240V Low Voltage, User-Friendly Control Interface To Inform Operator Of Transfer Switch And Power Source Status, Transfer To Emergency Time Delay 10 Seconds, Re-Transfer To Normal Time Delay 5 Minutes (WINCO97714366 97714366 97714 366)
Winco Generators 97714-366 ASCO 185 Series Non-SE Rated Automatic Transfer Switch, 100 Amps, NEMA 3R Housing, #14 to 4/0 AWG Wire Sizing, Single Phase, 2 Poles, 220-240V Low Voltage, User-Friendly Control Interface To Inform Operator Of Transfer Switch And Power Source Status, Transfer To Emergency Time Delay 10 Seconds, Re-Transfer To Normal Time Delay 5 Minutes (WINCO97714366 97714366 97714 366)

SKU: WINCO97714366

Brand: Winco Generators

Retrieving current price...      Add to Cart Qty:    
Estimate Shipping Cost: Choose the quantity to add to cart, press the "Add to Cart" button and in the Shopping Cart press "Calculate Shipping".
Availability: In Stock (see Disclaimer below).

 
 

 

Winco Generators 97714-366 ASCO 185 Series Non-SE Rated Automatic Transfer Switch, 100 Amps, NEMA 3R Housing, #14 to 4/0 AWG Wire Sizing, Single Phase, 2 Poles, 220-240V Low Voltage, User-Friendly Control Interface To Inform Operator Of Transfer Switch And Power Source Status, Transfer To Emergency Time Delay 10 Seconds, Re-Transfer To Normal Time Delay 5 Minutes, True Double-Throw Contacts With Inherent Mechanical Interlocking To Prevent Connection Of Generator And Utility Services, UL1008 Listed


General Information

Manufacturer

Winco Generators

Manufacturer Part Number

97714-366

Product Name

ASCO 185 Series Non-SE Rated Automatic Transfer Switch

UPC Code

 

Features

  • Residential/Light Commercial 1-PH Switches - User-friendly control interface to inform operator of transfer switch and power source status.

  • Double Throw Contacts - True double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility services.

  • Time Delays - Transfer to emergency time delay 10 seconds. Re-transfer to normal time delay 5 minutes.

  • UL1008 Listed - Handling total system load including motors and all other electrical loads. cUL listed for Canadian installations. Meets Article 702, NFPA-70 NEC requirements.

Specifications

Intended Applications Residential/Light Commercial
Amps 100
Phase Single
Poles 2
Housig NEMA 3R
Wire Sizing #14 to 4/0 AWG
Low Voltage 220-240V
Dimensions 16" x 10" x 24"
Weight 49 lbs
Withstand and Cole-On Ratings
WCR When Used With Specific Circuit Breakers 10-35 kA
WCR When Used With Current Limiting Fuses 100-200 kA
Neutral Configuration
Solid Standard
Ground Termination Standard
Voltage and Frequency Settings
Phase Selection Single
Pick Up Normal Source Voltage 198V
Drop Out Normal Source Voltage 154-187V
Pick Up Emergency Source Voltage 198V
Drop Out Emergency Source Voltage 165V
Frequency 50 or 60 Hz
Pick Up Emergency Source Frequency 48 or 57 Hz
Drop Out Emergency Source Frequency 43 or 51 Hz
Time Delay Settings
Override Normal Source Momentary Outage 1 or 3 Seconds
Transfer to Emergency 10 Seconds
Re-transfer to Normal Utility Power Loss Mode 5 Minutes
Engine Cool Down 2 or 5 Minutes
Override Emergency Source Momentary Outage 4 Seconds
Generator Exerciser 7 Day
Indication and Controls
Lead Connected to Normal LED
Lead Connected to Emergency LED
Normal Source Available LED
Emergency Source Available LED
Transfer Test Switch LED
Terminals For Remote Transfer Control Standard
Bypass Time Delay Switch LED
Transfer Inhibit LED

A-20191120-1851-130-E

*This item is BRAND NEW - not refurbished. It comes with all manufacturer supplied accessories, and full manufacturer's USA warranty.

*** DISCLAIMERS: 1) Availability is not always guaranteed: Please call or email us to double-check stock before placing your order. We ship from our inventory and also drop-ship from hundreds of suppliers. We try very hard to show only available products but sometimes products sell out before we can update the product webpage.  2) Some information may have been supplied by 3rd Party Content Suppliers: We are not responsible for Data or Image errors.  3) We do not offer Installation, Training or Technical Support on this product.***

Home  -  About  Us  -  Contact Us  -  FAQs  -  International Shipping - Store Policies - Privacy & Security Policies

 

Copyright © Sales Stores, All Rights Reserved